Reference Guide

Alert and Event Messages
77 Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Repair flow
System impact
Knowledge Base Article
for %(userName) (fs
%(mountPoint),
space for user is now below
soft quota limit.
0x01300801 MINOR TRUE FALSE
NAS server %(vdmname)
(fsid %(fsid)) is low on free
Provision additional storage
to the file system, or
increase its size.
The file system is running
low on free space. New
data writes and file
creations may start failing.
-
0x01300802 NONE FALSE FALSE
NAS server %(vdmname)
(fsid %(fsid)) free space is
-
The file system has
adequate free space.
-
0x01300901 NONE FALSE FALSE
NAS server %(vdmname)
(fsid %(fsid)) is operating
-
The file system is operating
normally.
-
0x01300902 MAJOR TRUE FALSE
File system %(fsname) in
NAS server %(vdmname)
(fsid %(fsid)) is offline due
to receiving an I/O error.
Contact your service
provider.
The file system has
received an I/O error and is
unmounted. There may be
a problem with the storage
device.
https://www.dell.com/support
/Article/SLN317195
0x01300903 MAJOR TRUE FALSE
NAS server %(vdmname)
(fsid %(fsid)) is offline after
Contact your service
provider.
The file system has
discovered internal
corruption and is
unmounted.
https://www.dell.com/support
/Article/SLN317195
0x01300904 MAJOR FALSE FALSE
NAS server %(vdmname)
(fsid %(fsid)) has been
Complete the planned
service procedure and
remount the FS using
'svc_recover -action mount'.
The file system has been
taken offline for service.
https://www.dell.com/support
/Article/SLN317195
0x01300905 MAJOR FALSE FALSE
NAS server %(vdmname)
(fsid %(fsid)) has
completed recovery and is
Remount the FS using
'svc_recover -action mount'
The file system has
completed recovery and is
waiting to be remounted.
https://www.dell.com/support
/Article/SLN317195
0x01300906 CRITICAL TRUE TRUE
system %(fsname) in NAS
server %(vdmname) (fsid
Contact your service
provider.
Recovery failed on the file
system, manual
intervention is likely
needed.
https://www.dell.com/support
/Article/SLN317195
0x01300A01 MINOR FALSE FALSE
on file system %(fsname) in
NAS server %(vdmname)
Contact your service
provider.
The file system's backing
storage LUN has reported a
potential impact; recovery
is recommended on the FS.
-
0x01300A02 NONE FALSE FALSE
NAS server %(vdmname)
(fsid %(fsid)) has no
suspected impacts from its
-
The file system's backing
storage LUN is not
reporting any impacts;
recovery is not
recommended on the FS.
-