Reference Guide
Alert and Event Messages
16 Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x00304401 NONE FALSE FALSE
The node lifecycle state
has changed from
%(old_value) to
%(fru_lifecycle_state).
- - -
0x00304402
NONE
FALSE
FALSE
Node is initializing.
-
-
-
0x00304403 CRITICAL TRUE TRUE Node has faulted.
Replace the faulted node.
Refer to the Installation and
Service Guide for more
information.
Data availability and
performance may be
degraded.
https://www.dell.com/support
/Article/SLN317238
0x00304404 MAJOR TRUE FALSE
Node has been physically
removed or shut down.
The node is not connected
or is in the process of
rebooting. Verify that the
node is properly connected,
or replace the node. Refer
to the Installation and
Service Guide for
information on replacing the
component.
Data availability and
performance may be
degraded.
https://www.dell.com/support
/Article/SLN317238
0x00304405
MINOR
FALSE
FALSE
Node is not initialized.
-
-
-
0x00304406
MINOR
FALSE
FALSE
Node preparation failed.
-
-
-
0x00304407
INFO
FALSE
FALSE
Node has been replaced.
-
-
-
0x00304902 MAJOR TRUE FALSE
The Node had failed with
Fatal Error.
- -
https://www.dell.com/support
/Article/SLN317236
0x00304F02 MAJOR TRUE FALSE
Node SAS port 1 is
connected to the wrong
LCC.
- -
https://www.dell.com/support
/Article/SLN317248
0x00304F03 MAJOR TRUE FALSE
Node SAS port 1 is
connected to the wrong
port of the LCC.
- -
https://www.dell.com/support
/Article/SLN317248
0x00304F04 MAJOR TRUE FALSE
Node SAS port 1 is not
connected to the Expansion
Enclosure of this Nodes
Base Enclosure.
- -
https://www.dell.com/support
/Article/SLN317248
0x00305002 MAJOR TRUE FALSE
Node SAS port 2 is
connected to the wrong
LCC.
- -
https://www.dell.com/support
/Article/SLN317248
0x00305003 MAJOR TRUE FALSE
Node SAS port 2 is
connected to the wrong
port of the LCC.
- -
https://www.dell.com/support
/Article/SLN317248
0x00305004 MAJOR TRUE FALSE
Node SAS port 2 is not
connected to the Expansion
Enclosure of this Node's
Base Enclosure.
- -
https://www.dell.com/support
/Article/SLN317248
0x00305302 MAJOR TRUE TRUE
Interconnect port 1 is
degraded.
Check the state of the peer
Node. One or both Nodes
may need to be restarted or
reseated in the
BaseEnclosure.
Cluster performance may
be degraded.
https://www.dell.com/support
/Article/SLN317241