Reference Guide

Alert and Event Messages
20 Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Repair flow
System impact
Knowledge Base Article
Installation and Service
Guide for more information.
node power supply is
healthy.
0x00305B08 INFO FALSE FALSE
- - -
0x00305C01 MAJOR TRUE FALSE
Appliance's %(location)
power supply unit has no
input power.
Ensure that there is power
to the appliance. If the
issue persists, replace the
power cable.
There is no impact on the
node as long as the peer
node power supply is
healthy.
https://www.dell.com/support
/Article/SLN317246
0x00305C02 NONE FALSE FALSE
appliance's %(location)
power supply unit has
- - -
0x00305C03 NONE FALSE FALSE
appliance's %(location)
power supply unit has
- - -
0x00305C04 MINOR TRUE FALSE
Node's %(location) PSU
input voltage is too low.
The Power Supply input
voltage must be high line
input. Low line input is not
acceptable, should use
step-up-transformer to set
up high line input.
- -
0x00306C01 INFO FALSE FALSE
(endurance) for bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) has
changed to
%(percent_endurance_rem
- - -
0x00306C02 MINOR TRUE TRUE
the drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) is low.
The remaining wear level
for this drive is
%(percent_endurance_rem
Contact your service
provider.
Drive will be used until the
drive fails or endurance is
exhausted.
https://www.dell.com/support
/Article/SLN317247
0x00306C03 MAJOR TRUE TRUE
the drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) is very
low and has reached a
critical level. The remaining
wear level for this drive is
%(percent_endurance_rem
Contact your service
provider.
Drive will be used until the
drive fails or endurance is
exhausted.
https://www.dell.com/support
/Article/SLN317247