Reference Guide

Alert and Event Messages
21 Dell EMC PowerStore Events and Alerts Reference Guide
Event Code Severity Alert Call Home Message Repair flow System impact Knowledge Base Article
0x00305502 NONE FALSE FALSE
Node IPMI BMC
connection state has
changed.
-
0x00305503 MAJOR TRUE TRUE
Node IPMI BMC
connection is no longer
active.
Shut down the node, unseat
it from the enclosure, and
reseat it again. If the issue
persists, contact your
service provider.
Hardware monitoring may
be degraded.
https://dell.com/support/artic
le/SLN317243
0x00305601 MINOR FALSE FALSE
Internal M.2 boot module
state has changed.
-
0x00305602 MAJOR TRUE TRUE
Internal M.2 boot module
slot in %(slot_num) used as
%(local_disk_purpose) is
empty.
Refer to the Installation and
Service Guide to install a
supported Internal M.2 boot
module.
Performance may be
degraded.
https://dell.com/support/artic
le/SLN317231
0x00305603 MAJOR TRUE TRUE
Internal M.2 boot module
slot %(slot_num) is
expected to be empty but
contains a disk.
https://dell.com/support/artic
le/SLN317231
0x00305604 MAJOR TRUE TRUE
Internal M.2 boot module in
slot %(slot_num) is not
supported.
Replace it with a supported
M.2 boot module. Refer to
the Installation and Service
Guide for more information.
Performance may be
degraded.
https://dell.com/support/artic
le/SLN317231
0x00305605 MAJOR FALSE FALSE
Internal M.2 boot module in
slot %(slot_num) has errors
or is faulted.
Replace the internal M.2
boot module. Refer to the
Installation and Service
Guide for more information.
Performance may be
degraded.
https://dell.com/support/artic
le/SLN317231
0x00305606 MAJOR TRUE TRUE
Internal M.2 boot module in
slot %(slot_num) is not
initialized.
If the issue persists, contact
your service provider.
Performance may be
degraded.
https://dell.com/support/artic
le/SLN317231
0x00305701 MINOR FALSE FALSE
Internal M.2 boot module
enabled state has changed.
-
0x00305702 MAJOR FALSE TRUE
The internal M.2 boot
module was deactivated
(disabled) by user request.
https://dell.com/support/artic
le/SLN317231
0x00305703 MAJOR FALSE TRUE
The cluster has disabled
the internal M.2 boot
module.
https://dell.com/support/artic
le/SLN317231
0x00305801 MINOR FALSE FALSE
Internal M.2 boot module
lifecycle state has changed.
-
0x00305802 MINOR FALSE FALSE
Internal M.2 boot module is
initializing.
-
0x00305803 MAJOR TRUE TRUE
Internal M.2 boot module
has faulted.
Replace the faulted
component. Refer to the
Installation and Service
Guide for more information.
Performance may be
degraded.
https://dell.com/support/artic
le/SLN317231