Table 10. NVDIMM-N Error Reporting (continued)
ID Event Message Recommended Action
MEM9033 An unsupported Non-Volatile Dual In-line
Memory Module (NVDIMM) device is of
unsupported configuration and unable to
operate as currently configured.
Review the memory configuration and
ensure the configuration is as per
memory rules that are defined in the
system Owner's Manual on the support
site.
MEM9034 The Non-Volatile Dual In-line Memory
Module (NVDIMM) device in the slot
[location] is not responding.
Remove and reinstall the Non-Volatile
Dual In-line Memory Module (NVDIMM)
device. If the issue persists, contact your
service provider. For information about
removing and reinstalling the NVDIMM,
see the system Owner's Manual on the
support site.
MEM9035 The Non-Volatile Dual In-line Memory
Module (NVDIMM) device in the slot
[location] cannot be configured to save
data during a power loss because of an
issue in the NVDIMM.
Remove and reinstall the Non-Volatile
Dual In-line Memory Module (NVDIMM)
device. If the issue persists, contact your
service provider. For information about
removing and reinstalling the NVDIMM,
see the system Owner's Manual on the
support site.
MEM9036 The Non-Volatile Dual In-line Memory
Module (NVDIMM) devices are placed in
write-protect mode because the system
may not provide sufficient power to save
data if there is power loss.
Review any preceding power or battery
entries in the log and resolve the issues.
See your documentation for details on
how to view the log.
MEM9037 The Non-Volatile Dual In-line Memory
Module (NVDIMM) device in the slot
[location] has reached the end of
supported life duration and is placed in
write-protect mode.
Replace the Non-Volatile Dual In-line
Memory Module (NVDIMM) device.
For information about removing and
reinstalling the NVDIMM, see the system
Owner's Manual on the support site.
MEM9038 The Non-Volatile Dual In-line Memory
Module (NVDIMM) device in the slot
[location] has lost persistency and is
placed in write-protect mode.
Remove and reinstall the Non-Volatile
Dual In-line Memory Module (NVDIMM)
device. If the issue persists, contact the
service provider. For information about
removing and reinstalling the NVDIMM,
see the system Owner's Manual on the
support site.
MEM9050 The Non-Volatile Dual In-line Memory
Module (NVDIMM) device in the slot
[location] has regained persistency and
is available for use.
No response action required.
MEM9072 The system memory has faced an
uncorrectable multi-bit memory error in
the nonexecution path of a memory
device at the location <location>.
If the issue persists, contact your service
provider. To select a convenient contact
method, see the product documentation
available on the support site.
BAT0015 The NVDIMM battery is low. Leave the server powered on to allow
the NVDIMM-N Battery to charge. If
the issue persists, contact your service
provider. For information about removing
and reinstalling the NVDIMM, see the
system Owner's Manual on the support
site.