CLI Guide
Table 79. Details of RACADM Proxy (continued)
Table 80. Details of CMC and iDRAC privilege for an operation (continued)
User Configuration Administrator Configure User
Clear Logs Administrator Logs
Chassis Control Administrator System Control
Server Administrator System Control
Test Alert User System Operations
Debug Command Administrator Debug
Fabric x Administrator (where x is A, B, or C) System Control
● When CMC is not placed on the network, the import, export, and file operation commands to CIFS,
NFS, or FTP will fail.
● When the Remote or Local RACADM Proxy operation is in progress, if the iDRAC is reset, then the
Proxy operation fails and the output is not displayed in Remote or Local RACADM.
● When racadm getsystem.ChassisControl.ChassisManagementMonitoring attribute is
set to monitor, all the users including root users can only view the attribute.
To configure, set the attribute to monitor and manage in CMC.
Input
● -u — Specifies the user name of the remote share that stores the catalog file.
● -p — Specifies the password of the remote share that stores the catalog file.
● -r — Specifies the iDRAC IP address connected to CMC.
Example
Local RACADM
racadm getractime --proxy
Remote RACADM
racadm getractime -u root -p xxx -r 192.168.0 getractime --proxy
racdump
Table 81. Details of racdump
Description Provides a single command to get dump, status, and general iDRAC board information.
To run this subcommand, you must have the Debug permission.
● General System/RAC Information
● Coredump Information
● Network Interface Statistics
● Session Information
● Process Information
● RAC Firmware Build Log
NOTE: The RAC debug logs are not part of Local and Remote RACADM. It is available only on
Firmware RACADM
Synopsis
racadm racdump
RACADM Subcommand Details 107