Users Guide

Storage
Modules
Below picture shows how the NVDIMM-N devices will appear in the Persistent Memory tab under the Storage heading in the
left menu bar. The first column is an ID to uniquely identify the NVDIMM-N in the event the information is needed for
troubleshooting. The next column indicates free space and it is expected to be 0 B for all NVDIMM-N devices that are fully
mapped and operated correctly. Health should be Normal. Detailed explanation of Health section is provided in Overall health
Status below.
Translation of ID to physical NVDIMM-N in host system can be seen below.
Table 14. Translation of ID to physical NVDIMM-N in host system
ID (Hex) Decimal Physical Location (L->R) Silk screen slot name
0x1 16 Socket 0 , IMC0, Channel 0 , Slot 1 A7
0x11 17 Socket 0 , IMC0, Channel 1 , Slot 1 A8
0x21 33 Socket 0 , IMC0, Channel 2 , Slot 1 A9
0x101 257 Socket 0 , IMC1, Channel 0 , Slot 1 A10
0x111 273 Socket 0 , IMC1, Channel 1 , Slot 1 A11
0x121 289 Socket 0 , IMC1, Channel 2 , Slot 1 A12
0x1001 4097 Socket 1 , IMC0, Channel 0 , Slot 1 B7
0x1011 4113 Socket 1 , IMC0, Channel 1 , Slot 1 B8
0x1021 4129 Socket 1 , IMC0, Channel 2 , Slot 1 B9
0x1101 4353 Socket 1 , IMC1, Channel 0 , Slot 1 B10
0x1111 4369 Socket 1 , IMC1, Channel 1 , Slot 1 B11
0x1121 4385 Socket 1 , IMC1, Channel 2 , Slot 1 B12
Namespaces
All Namespace names are automatically generated by ESXi when the NVDIMM-N modules are detected on startup. These
Namespaces will persist over warm reset and cold boot of the system after first detection/creation.
Figure 31. Namespaces