CLI Guide
Table Of Contents
- Integrated Dell Remote Access Controller 9 RACADM CLI Guide
- Contents
- Introduction
- Running Get and Set
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- help and help subcommand
- arp
- autoupdatescheduler
- bioscert
- biosscan
- cd
- cd ..
- clearasrscreen
- clearpending
- closessn
- clrsel
- connect
- coredump
- coredumpdelete
- diagnostics
- driverpack
- eventfilters
- exposeisminstallertohost
- fcstatistics
- frontpanelerror
- fwupdate
- gethostnetworkinterfaces
- getled
- getniccfg
- getraclog
- getractime
- getremoteservicesstatus
- getsel
- getsensorinfo
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- groupmanager
- httpsbootcert
- hwinventory
- ifconfig
- infinibandstatistics
- inlettemphistory
- jobqueue
- krbkeytabupload
- lclog
- license
- netstat
- networktransceiverstatistics
- nicstatistics
- ping
- ping6
- racadm proxy
- racdump
- racreset
- racresetcfg
- recover
- remoteimage
- rollback
- sekm
- serialcapture
- sensorsettings
- serveraction
- setled
- setniccfg
- sshpkauth
- sslcertdelete
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslkeyupload
- sslresetcfg
- storage
- supportassist
- swinventory
- switchconnection
- systemerase
- systemperfstatistics
- techsupreport
- testalert
- testemail
- testrsyslogconnection
- testtrap
- traceroute
- traceroute6
- update
- usercertupload
- usercertview
- vflashpartition
- vflashsd
- vmdisconnect
- iDRAC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgStaticLanNetworking
- cfgNicStaticEnable (Read or Write)
- cfgNicStaticIPv4Enable (Read or Write)
- cfgNicStaticIpAddress (Read or Write)
- cfgNicStaticUseDhcp (Read or Write)
- cfgNicStaticNetmask (Read or Write)
- cfgNicStaticGateway (Read or Write)
- cfgDNSStaticServersFromDHCP (Read or Write)
- cfgDNSStaticServer1 (Read or Write)
- cfgDNSStaticServer2 (Read or Write)
- cfgDNSStaticDomainName(Read or Write)
- cfgDNSStaticDomainNameFromDHCP (Read or Write)
- cfgRemoteHosts
- cfgRhostsFwUpdateTftpEnable (Read or Write)
- cfgRhostsFwUpdateIpAddr (Read or Write)
- cfgRhostsFwUpdatePath (Read or Write)
- cfgRhostsSmtpServerIpAddr (Read or Write)
- cfgRhostsSyslogEnable (Read or Write)
- cfgRhostsSyslogPort (Read or Write)
- cfgRhostsSyslogServer1 (Read or Write)
- cfgRhostsSyslogServer2 (Read or Write)
- cfgRhostsSyslogServer3 (Read or Write)
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgSerialBaudRate (Read or Write)
- cfgSerialConsoleEnable (Read or Write)
- cfgSerialConsoleQuitKey (Read or Write)
- cfgSerialConsoleIdleTimeout (Read or Write)
- cfgSerialConsoleNoAuth (Read or Write)
- cfgSerialConsoleCommand (Read or Write)
- cfgSerialHistorySize (Read or Write)
- cfgSerialCom2RedirEnable (Read or Write)
- cfgSerialSshEnable (Read or Write)
- cfgOobSnmp
- cfgRacTuning
- cfgRacTuneConRedirPort (Read or Write)
- cfgRacTuneRemoteRacadmEnable (Read or Write)
- cfgRacTuneCtrlEConfigDisable
- cfgRacTuneHttpPort (Read or Write)
- cfgRacTuneHttpsPort (Read or Write)
- cfgRacTuneIpRangeEnable (Read or Write)
- cfgRacTuneIpRangeAddr (Read or Write)
- cfgRacTuneIpRangeMask (Read or Write)
- cfgRacTuneSshPort (Read or Write)
- cfgRacTuneConRedirEnable (Read or Write)
- cfgRacTuneConRedirEncryptEnable (Read or Write)
- cfgRacTuneAsrEnable (Read or Write)
- cfgRacTuneDaylightOffset (Read Only)
- cfgRacTuneTimezoneOffset (Read Only)
- cfgRacTuneLocalServerVideo (Read or Write)
- cfgRacTuneLocalConfigDisable (Read or Write)
- cfgRacTuneWebserverEnable (Read or Write)
- cfgRacTuneVirtualConsoleAuthorizeMultipleSessions (Read or Write)
- cfgRacTunePluginType (Read or Write)
- ifcRacManagedNodeOs
- cfgRacVirtual
- cfgServerInfo
- cfgActiveDirectory
- cfgADSSOEnable (Read or Write)
- cfgADDomainController1 (Read or Write)
- cfgADDomainController2 (Read or Write)
- cfgADDomainController3 (Read or Write)
- cfgADRacName (Read or Write)
- cfgADRacDomain (Read or Write)
- cfgADAuthTimeout (Read or Write)
- cfgADEnable (Read or Write)
- cfgADType (Read or Write)
- cfgADGlobalCatalog1 (Read or Write)
- cfgADGlobalCatalog2 (Read or Write)
- cfgADGlobalCatalog3 (Read or Write)
- cfgADCertValidationEnable (Read or Write)
- cfgADDcSRVLookupEnable (Read or Write)
- cfgADDcSRVLookupbyUserdomain (Read or Write)
- cfgADDcSRVLookupDomainName (Read or Write)
- cfgADGcSRVLookupEnable (Read or Write)
- cfgADGcRootDomain (Read or Write)
- cfgLDAP
- cfgLDAPBaseDN (Read or Write)
- cfgLDAPBindPassword (Write Only)
- cfgLDAPCertValidationEnable (Read or Write)
- cfgLDAPEnable (Read or Write)
- cfgLDAPGroupAttribute (Read or Write)
- cfgLDAPGroupAttributeIsDN (Read or Write)
- cfgLDAPPort (Read or Write)
- cfgLDAPSearchFilter (Read or Write)
- cfgLDAPServer (Read or Write)
- cfgLDAPUserAttribute (Read or Write)
- cfgLdapRoleGroup
- cfgStandardSchema
- cfgThermal
- cfgIpmiSol
- cfgIpmiLan
- cfgIpmiPetIpv6
- cfgIpmiPef
- cfgIpmiPet
- cfgUserDomain
- cfgServerPower
- cfgServerPowerStatus (Read Only)
- cfgServerPowerAllocation (Read Only)
- cfgServerActualPowerConsumption (Read Only)
- cfgServerPowerCapEnable (Read or Write)
- cfgServerMinPowerCapacity (Read Only)
- cfgServerMaxPowerCapacity (Read Only)
- cfgServerPeakPowerConsumption (Read Only)
- cfgServerPeakPowerConsumptionTimestamp (Read Only)
- cfgServerPowerConsumptionClear (Write Only)
- cfgServerPowerCapWatts (Read or Write)
- cfgServerPowerCapBtuhr (Read or Write)
- cfgServerPowerCapPercent (Read or Write)
- cfgServerPowerLastHourAvg (Read Only)
- cfgServerPowerLastDayAvg (Read Only)
- cfgServerPowerLastWeekAvg (Read Only)
- cfgServerPowerLastHourMinPower (Read Only)
- cfgServerPowerLastHourMinTime (Read Only)
- cfgServerPowerLastHourMaxPower (Read Only)
- cfgServerPowerLastHourMaxTime (Read Only)
- cfgServerPowerLastDayMinPower (Read Only)
- cfgServerPowerLastDayMinTime (Read Only)
- cfgServerPowerLastDayMaxPower (Read Only)
- cfgServerPowerLastDayMaxTime (Read Only)
- cfgServerPowerLastWeekMinPower (Read Only)
- cfgServerPowerLastWeekMinTime (Read Only)
- cfgServerPowerLastWeekMaxPower (Read Only)
- cfgServerPowerLastWeekMaxTime (Read Only)
- cfgServerPowerInstHeadroom (Read Only)
- cfgServerPowerPeakHeadroom (Read Only)
- cfgServerActualAmperageConsumption (Read Only)
- cfgServerPeakAmperage (Read Only)
- cfgServerPeakAmperageTimeStamp (Read Only)
- cfgServerCumulativePowerConsumption (Read Only)
- cfgServerCumulativePowerConsumptionTimeStamp (Read Only)
- cfgServerCumulativePowerClear (Write Only)
- cfgServerPowerPCIeAllocation (Read or Write)
- cfgServerPowerSupply
- cfgIPv6LanNetworking
- cfgIPv6Enable (Read or Write)
- cfgIPv6Address1 (Read or Write)
- cfgIPv6Gateway (Read or Write)
- cfgIPv6AutoConfig (Read or Write)
- cfgIPv6PrefixLength (Read or Write)
- cfgIPv6LinkLocalAddress (Read Only)
- cfgIPv6Address2 (Read Only)
- cfgIPv6Address3 (Read Only)
- cfgIPv6Address4 (Read Only)
- cfgIPv6Address5 (Read Only)
- cfgIPv6Address6 (Read Only)
- cfgIPv6Address7 (Read Only)
- cfgIPv6Address8 (Read Only)
- cfgIPv6Address9 (Read Only)
- cfgIPv6Address10 (Read Only)
- cfgIPv6Address11 (Read Only)
- cfgIPv6Address12 (Read Only)
- cfgIPv6Address13 (Read Only)
- cfgIPv6Address14 (Read Only)
- cfgIPv6Address15 (Read Only)
- cfgIPv6DNSServer1 (Read or Write)
- cfgIPv6DNSServersFromDHCP6 (Read or Write)
- cfgIpv6StaticLanNetworking
- cfgIPv6StaticEnable (Read or Write)
- cfgIPv6StaticAddress1 (Read or Write)
- cfgIPv6StaticGateway (Read or Write)
- cfgIPv6StaticPrefixLength (Read or Write)
- cfgIPv6StaticAutoConfig (Read/Write)
- cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)
- cfgIPv6StaticDNSServer1 (Read or Write)
- cfgIPv6StaticDNSServer2 (Read or Write)
- cfgIPv6DNSServer2 (Read or Write)
- cfgIPv6URL
- cfgIpmiSerial
- cfgIpmiSerialBaudRate (Read or Write)
- cfgIpmiSerialChanPrivLimit (Read or Write)
- cfgIpmiSerialConnectionMode (Read or Write)
- cfgIpmiSerialDeleteControl (Read or Write)
- cfgIpmiSerialEchoControl (Read or Write)
- cfgIpmiSerialFlowControl (Read or Write)
- cfgIpmiSerialHandshakeControl (Read or Write)
- cfgIpmiSerialInputNewLineSequence (Read or Write)
- cfgIpmiSerialLineEdit (Read or Write)
- cfgIpmiSerialNewLineSequence (Read or Write)
- cfgSmartCard
- cfgNetTuning
- cfgSensorRedundancy
- cfgVFlashSD
- cfgVFlashPartition
- cfgLogging
- cfgRacSecurity
- New Groups and Objects for iDRAC9
- Legacy and New Groups and Objects
- Error Codes
Table 101. Details of storage (continued)
createsecuritykey, createvd, deletesecuritykey,
deletevd, encryptvd, enclosures, emms, fans, hotspare,
importconfig, ccheck, cryptographicerase, preparetoremove, blink,
unblink, cancelcheck, renamevd, cancelbgi, rebuild, cancelrebuild,
capacityexpanon, raidlevelmigrationinit, modifysecuritykey, psus,
pdisks, resetconfig, tempprobes, vdisks, patrolread, forceonline,
forceoffline,replacephysicaldisk,unlock,and setbootvd.
NOTE: iSM must be running on the operating system to run the preparetoremove method:
● To create, delete, and secure the virtual disks, to start or stop the consistency check on the specified
virtual disk, run the following command:
racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}
[-wp {wt|wb|wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|
128k|256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp
{enabled|disabled|default}] [-name <VD name>] [-size <VD size>{b|k|m|g|
t}] [-T10PIEnable] [-sd <secureDisk>]
NOTE:
○ T10PI is no longer supported on PERC controllers.
○ If the <VD name> exceeds 15 characters when running the createvd command, it gets
corrected to a length of 15 characters once the command is completed successfully.
racadm storage init:<VD FQDD> -speed {fast|full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -xxx
<passphrase>
racadm storage modifysecuritykey:<Controller FQDD> -key <Key id>-xxx
<old passphrase> -xxx <new passphrase>
racadm storage deletesecuritykey:<Controller FQDD>
racadm storage ccheck:<VD FQDD>
racadm storage cancelcheck:<VD FQDD>
● To set virtual disk as bootvd and replace physical disk in virtual disk:
racadm storage setbootvd:<Controller FQDD> -vd <VD FQDD >
racadm storage replacephysicaldisk:<Source PD FQDD > -dstpd
<Destination PD FQDD>
RACADM Subcommand Details
129