CLI Guide

Example Display entire log.
racadm getsel
Display number of records in log.
racadm getsel -i
getsensorinfo
Table 36. Details of getsensorinfo
Description Displays the status for system sensors.
NOTE: For the Dell PowerEdge FX2 chassis with the
FM120x4 server, the power-related information is not
displayed.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input -c—Compact output format.
NOTE: Chassis Controller is supported only on Dell PowerEdge FX2, and GPU sensors are displayed only on PowerEdge
C4130 servers.
Example
racadm getsensorinfo
Sensor Type : POWER
Table 37. racadm getsensorinfo Sensor Type : POWER
<Sensor Name> <Status> <Type>
PS1 Status Present AC
Sensor Type : TEMPERATURE
Table 38. Sensor Type : TEMPERATURE
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board
Inlet Temp
Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board
Exhaust Temp
Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Sensor Type : FAN
Table 39. Sensor Type : FAN
<Sensor Name> <Status> <Reading> <lc> <uc> <PWM %>
System Board
Fan1 RPM
Ok 5880 RPM 600 RPM NA 21%
System Board
Fan2 RPM
Ok 6000 RPM 600 RPM NA 0%
RACADM Subcommand Details 71