CLI Guide

Example Display entire log.
racadm getsel
Display number of records in log.
racadm getsel -i
getsensorinfo
Table 34. Details of getsensorinfo
Description Displays the status for system sensors.
NOTE: For Dell PowerEdge FX2 chassis with FM120x4
server, the power related information is not displayed.
NOTE: General purpose graphical processing unit
(GPGPU) status is displayed only on PowerEdge C4130
servers.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input -c — Compact output format.
NOTE: Chassis Controller is supported only on Dell PowerEdge FX2 and GPU sensors are displayed only on PowerEdge
C4130 servers.
Table 35. Example
<Num> <sensorName> <status>
1 IO-Cable OK
2 FPC-Cable OK
Table 36. Sensor Type
<Sensor Name> <Status> <Type>
PS1 Status Present AC
Table 37. Sensor info
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board
Inlet Temp
Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board
Exhaust Temp
Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Table 38. Temperature sensor
<Sensor Name> <Status> <Reading> <lc> <uc> <PWM %>
System Board
Fan1 RPM
Ok 5880 RPM 600 RPM NA 21%
System Board
Fan2 RPM
Ok 6000 RPM 600 RPM NA 0%
72 RACADM Subcommand Details