CLI Guide
cfgSensorRedundancyPolicy (Read or Write)
Table 357. Details of cfgSensorRedundancyPolicy
Description
Sets the power supply redundancy policy.
Legal Values
• 2 — N/A, for systems that are not supported
• 3 — Non Redundant
• 4–1+1 Redundant
• 4–2+1 Redundant
• 16–2+2 Redundant
Default
Any legal value at that particular execution instance.
cfgSensorRedundancyCapabilities (Read Only)
Table 358. Details of cfgSensorRedundancyCapabilities
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to know which values can
be set for cfgSensorRedundancyPolicy.
Legal Values
A bit mask. More than 1 bit can be set at a time to indicate multiple redundancy support.
• 0- N/A, for systems that are not supported
• 1- Non-Redundant
• 2- 1+1 — Redundant
• 4- 2+1 — Redundant
• 8- 2+2 — Redundant
Default
0
cfgSensorRedundancyStatus (Read Only)
Table 359. Details of cfgSensorRedundancyStatus
Description
Indicates the redundancy status. The status is N/A on platforms that do not support the power supply sensor
redundancy.
Legal Values
String:
• N/A
• Full
• Lost
• Degraded
Default
None
cfgVFlashSD
This group is used to configure the properties for the Virtual Flash SD card.
NOTE:
If the vFlash card is present but is not enabled, the query for any property under this group displays:
ERROR: vFlash is not enabled.
222
iDRAC Property Database Group and Object Descriptions