CLI Guide

# idRacVersionInfo=P21
# idRacBuildInfo=200708301525
# idRacName=CMC-1
racadm getconfig -g idRacInfo
# idRacType=16
# idRacProductInfo=Integrated Dell Remote Access Controller
# idRacDescriptionInfo=This system component provides a complete set of remote management
functions for Dell PowerEdge Servers
# idRacVersionInfo=1.06.06
# idRacBuildInfo=15
# idRacName=idrac-GSRS3V1
cfgStaticLanNetworking
This group contains parameters to configure the device NIC for IPv4.
NOTE:
A few objects in this group may require the device NIC to be reset, that may cause a brief loss in connectivity.
cfgNicStaticEnable (Read or Write)
Table 118. Details of cfgNicStaticEnable
Description
Enables or disables the NIC.
Legal Values
0 — Disabled
1 — Enabled
Default
1 — Enabled
NOTE: If this object is modified, then the object cfgNicEnable is also modified.
cfgNicStaticIPv4Enable (Read or Write)
Table 119. Details of cfgNicStaticIPv4Enable
Description
Enables or disables the IPv4 stack.
Legal Values
0 — Disabled
1 — Enabled
Default
1 — Enabled
NOTE: If this object is modified, then the object cfgNicIPv4Enable is also modified.
cfgNicStaticIpAddress (Read or Write)
Table 120. Details of cfgNicStaticIpAddress
Description
Returns or sets the current IPv4 address.
NOTE: Only set the current IPv4 address if cfgNicUseDhcp is set to 0(false).
Legal Values
Any Valid IPv4 address
158 iDRAC Property Database Group and Object Descriptions