CLI Guide

Table Of Contents
Table 17. Details of clrsel (continued)
Example
racadm clrsel
The SEL was cleared successfully
connect
Table 18. Details of connect
Description
Allows you to connect to the switch or blade serial console.
NOTE: This subcommand is only supported on the firmware interface.
Synopsis
racadm connect [-b] -m <module>
Input
-bbinary mode.
NOTE: If -b is used, CMC must be reset to terminate connect.
-mmodule, and can be one of the following values:
server-<n>where n = 1 to 16
server-<nx>where n = 1 to 8 and x = a to d
switch-nwhere n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Examples
To connect to I/O Module 1 serial console:
racadm connect -m switch-1
To connect to server 1 serial console:
racadm connect -m server-1
coredump
Table 19. Details of coredump
Description Displays detailed information related to any recent critical issues that have occurred with iDRAC.
The coredump information can be used to diagnose these critical issues.
If available, the coredump information is persistent across iDRAC power cycles and remains
available until either of the following conditions occur:
The coredump information is deleted using the coredumpdelete subcommand.
For more information about clearing the coredump, see the coredumpdelete.
NOTE: To use this subcommand, you must have the Execute Debug privilege.
Synopsis
racadm coredump
Example
racadm coredump
There is no coredump currently available.
racadm coredump
Feb 19 15:51:40 (none) last message repeated 5 times
Feb 19 15:52:41 (none) last message repeated 4 times
Feb 19 15:54:12 (none) last message repeated 4 times
Feb 19 15:56:11 (none) last message repeated 2 times
Feb 22 11:46:11 (none) kernel:
RACADM Subcommand Details 41