Users Guide
Information Update 9
E0D76 BP DRIVE n
1x2 DRIVE FAIL n
SCSI CONNECTOR
Faulty or improperly installed
hard drive or RAID controller.
See "Troubleshooting SCSI Hard
Drives" "Troubleshooting a RAID
Controller Card, " and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.
EB107 PROC BUS ERR
PROC INIT ERR
PROC PROTOCOL
ERR
Faulty or improperly installed
microprocessor or system board.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
EB107 PCIE FATAL ERR
CHIPSET ERR
Faulty or improperly installed
PCI-e card.
Faulty or improperly installed
riser card.
Faulty system board.
Remove and reseat the PCI-e
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" in your
Installation and Troubleshooting
Guide.
Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide.
If the problem persists, the riser
card or system board is faulty.
See "Getting Help" in your
Installation and Troubleshooting
Guide.
EB107 MEMORY MIRRORED Memory mirroring enabled. Information only.
EB107 MEMORY SPARED Memory spare bank enabled. Information only.
EFFF2 ROMB PRESENCE Integrated RAID controller is
activated.
Information only.
IB110 SBE LOG DISABLED
LOGGING DISABLED
Information only.
IS000 INTRUSION System cover has been removed. Information only
NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary"
in your User’s Guide.
Table 1-4. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions