Users Guide
Table Of Contents
- Rack Installation Guide
- Contents
- Four-Post Rack Installation
- Safety Instructions
- General Installation Instructions
- Removing the Rack Doors
- Marking the Rack
- Configuring the Sliding Rail Assemblies (Sliding Rail Kits Only)
- Installing Chassis Static Rail Modules (Static Rail Kits Only)
- Installing the Mounting Rails in the Rack
- Installing the System in the Rack
- Replacing the Rack Doors
- Installing the Tray and Cable-Management Arm (Sliding Rail Kits Only)
- Removing the System From the Rack
- Two-Post Rack Installation
- Index
- Guide d'installation du rack
- Sommaire
- Installation dans un rack à quatre montants
- Consignes de sécurité
- Consignes générales d'installation
- Retrait des portes du rack
- Marquage du rack
- Configuration des assemblages à glissière (kits avec rails coulissants uniquement)
- Installation des modules de rails statiques pour le châssis (kits avec rails statiques uniquement)
- Installation des rails de montage dans le rack
- Installation du système dans l'armoire rack
- Remise en place des portes du rack
- Installation du chemin de câbles et du passe-câbles (kits avec rails coulissants uniquement)
- Retrait du système de l'armoire rack
- Installation dans un rack à deux montants
- Index
- Rack-Installationsanleitung
- Inhalt
- Montage in einem Rack mit vier Stützen
- Sicherheitshinweise
- Allgemeine Installationsanleitung
- Abnehmen der Rack-Türen
- Markieren des Racks
- Konfiguration der Gleitschienensätze (nur bei Kits mit Gleitschienen)
- Installation der festen Schienenmodule am Gehäuse (nur bei Kits mit festen Schienen)
- Installation der Montageschienen im Rack
- Installation des Systems im Rack
- Wiederanbringen der Rack-Türen
- Installation der Ablage und des Kabelführungsarms (nur bei Kits mit Gleitschienen)
- Entfernen des Systems aus dem Rack
- Montage in einem Zwei-Stützen-Rack
- Index
- ラック取り付けガイド
- Guía de instalación del rack
- Contenido
- Instalación del rack de cuatro postes
- Instrucciones de seguridad
- Instrucciones generales de instalación
- Extracción de las puertas del rack
- Marcado del rack
- Configuración de los ensamblajes de rieles deslizantes (únicamente en los kits de rieles deslizantes)
- Instalación de los módulos de rieles estáticos del chasis (únicamente en los kits de rieles estáticos)
- Instalación de los rieles de montaje en el rack
- Instalación del sistema en el rack
- Colocación de las puertas del rack
- Instalación de la bandeja y el brazo para tendido de cables (únicamente en los kits de rieles deslizantes)
- Extracción del sistema del rack
- Instalación del rack de dos postes
- Índice
Two-Post Rack Installation 31
Wide-Hole Spacing Racks
Racks with wide-hole spacing have an alternating pattern of two holes per rack unit with center-to-center
hole spacing (beginning at the top hole of a 1-U space) of 31.7 mm and 12.7 mm (1.25 inches and 0.5 inch)
for the front and back vertical columns of holes (see Figure 2-3).
Figure 2-3. Two-Post, Open-Frame Relay Rack Wide-Hole Spacing
To mark the rack, perform the following steps:
1
Place a mark on the rack's front vertical rails where you want to locate the bottom of the system you are
installing in the two-post rack.
The bottom of each 1-U space is at the middle of the narrowest metal area between holes.
NOTE: If your rack has wide-hole spacing, go to step 3.
2
Place a mark 44 mm (1.75 inches) above the original mark you made (or count up three holes in a rack
with universal-hole spacing) (see Figure 2-2).
Each 1 U (44 mm, or 1.75 inches) of vertical space on a rack with universal-hole spacing has three holes
with center-to-center spacing between holes (beginning at the top of a 1-U space) of 15.9 mm,
15.9 mm, and 12.7 mm (0.625 inch, 0.625 inch, and 0.5 inch) (see Figure 2-2).
NOTE: If your rack has universal-hole spacing, you have completed the procedure for marking the rack.
3
Place a mark 44 mm (1.75 inches) above the original mark you made (or count up to the next hole in
the rack with wide-hole spacing (see Figure 2-3).
Each 1 U (44 mm, or 1.75 inches) of vertical space on a rack with wide-hole spacing has two holes with
center-to-center spacing between holes (beginning at the top of a 1-U space) of 31.7 mm (1.25 inches)
(see Figure 2-3).
1 U (44 mm or 1.75 inches)
12.7 mm (0.5 inch)
31.7 mm (1.25 inches)