Reference Guide

System Management Commands 1739
Different fields in the display are explained as follows:
Example – Status Parameters for NSF
The show switch command is used to display which unit is the management
unit and which is the backup unit. Global Status Parameters for NSF are
explained as follows:
Unit Description
Switch This field displays the unit identifier assigned to
the switch.
Management Status This field indicates whether the switch is the
Management Switch, a stack member, or the
status is unassigned.
Preconfigured Model Identifier This field displays the model identifier of a
preconfigured switch ready to join the stack.
The Model Identifier is a 32-character field
assigned by the switch manufacturer to identify
the switch.
Plugged-In Model Identifier This field displays the model identifier of the
switch in the stack. Model Identifier is a 32-
character field assigned by the switch
manufacturer to identify the switch.
Switch Status This field indicates the switch status. Possible
values for this state are: OK, Unsupported,
CodeMismatch, ConfigMismatch, or
NotPresent
Code Version This field indicates the detected version of code
on this switch.
Parameter Description Range Default
NSF
Administrative
Status
Whether nonstop forwarding is
administratively enabled or disabled
Enabled
Disabled
Enabled
NSF Operational
Status
Indicates whether NSF is enabled
on the stack.
Enabled
Disabled
None
2CSPC4.XModular-SWUM204.book Page 1739 Friday, March 15, 2013 9:24 AM