User's Manual

Step 4 Install the RAID Controller
Perform the following steps to install the controller:
1. Select a 3.3-V PCI slot and align the controller PCI bus connector to the slot.
2. Press down gently but firmly to make sure that the controller is properly seated in the slot, as shown in Figure3-3.
3. Screw the bracket to the system chassis.
Figure 3-3. Inserting the RAID Controller into a PCI Slot
Step 5 Connect SCSI Cables and SCSI Devices
Connect the SCSI cables to the SCSI connectors and SCSI devices.
Connect SCSI Devices
Perform the following steps to connect SCSI devices.
1. Disable termination on any SCSI device that does not sit at the end of the SCSI bus.
2. Configure all SCSI devices to supply TermPWR..
3. Set proper target IDs (TIDs) for all SCSI devices.
Pin-2 TXD (Transmit Data)
Pin-3 GND (Ground)
J16
Onboard BIOS Enable
2-pin header
No jumper = Enabled (Default setting)
Jumpered = Disabled
J17
TERMPWR Enable Channel 0
2-pin header
Jumper installed enables TERMPWR from the PCI bus. Default setting.
No jumper installed enables TERMPWR from the SCSI bus. (See J4 and J5)
J18
TERMPWR Enable Channel 1
2-pin header
J19
External SCSI Channel 1
connector
68-pin
connector
External very-high density SCSI bus connector. Connection is optional.
J23
Serial EEPROM
2-pin header
To CLEAR configuration data, install a jumper.
D17 - D24
LED (located on back of card)

Indicate problems with the card.