Owner's Manual

iSCSI Cluster Setup for the PowerVault Enclosure 31
Setting Up the iSCSI Cluster for PowerVault
MD3000i and MD1000 Expansion Enclosures
Task 1: Setting up the Hardware
Direct-attached iSCSI clusters are limited to two nodes only.
Figure 5-1. Cabling iSCSI Direct-Attached Clusters
To configure your nodes in a direct-attached configuration, see Figure 5-1,
and complete the following steps:
1
Connect one CAT 5e/6 cable from a port (iSCSI HBA or NIC) of node 1
to the
In-0
port of RAID controller 0 in the PowerVault MD3000i
storage enclosure.
2
Connect one CAT 5e/6 cable from the other port (iSCSI HBA or NIC) of
node 1 to the
In-0
port of RAID controller 1 in the PowerVault MD3000i
storage enclosure.
3
Connect one CAT 5e/6 cable from a port (iSCSI HBA or NIC) of node 2
to the
In-1
port of RAID controller 0 in the PowerVault MD3000i
storage enclosure.
Standalone (One or Two) Host System
LAN/WAN
PowerVault MD3000i
RAID Enclosure
(Dual) Controller
Two-Node Cluster
Ethernet
Management
Port
CAT 5e/6 (Public NIC)
Fiber Optic Cables
Lnx_Stnwt.book Page 31 Jeudi, 16. juillet 2009 1:36 13