Reference Guide

Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or a user has cancelled the initialization.
Action: If a physical disk has failed, then replace the physical disk
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2080
Description Physical disk initialization failed.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk has failed or is not functioning.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the
disk that has a red X for its status. Restart the initialization.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID 2081
Description
Virtual disk reconfiguration failed.
Severity Critical / Failure / Error
Cause and Action Hardware RAID:
Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have
cancelled the reconfiguration.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the
disk that displays a red X in the status field.
If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the
reconfiguration.
Software RAID:
Perform a backup with the Verify option.
If the file backup fails, try to restore the failed file from a previous backup.
When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
Recreate a new Virtual Disk with new drives.
Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Storage Management Message Reference 63