Reference Guide

Cause and Action Cause: This alert is provided for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2415
Description Controller battery is discharging.
Severity Informational
Cause and Action Cause: The battery learn cycle has started.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2416
Description
Disk medium error detected.
Severity Warning / Non-critical
Cause and Action Cause: A part of the physical disk is damaged.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
903
Event ID 2417
Description
There is an unrecoverable medium error detected on virtual disk.
Severity Critical / Failure / Error
Cause and Action Cause: Unrecoverable medium error found on one or more member physical disks of a virtual disk.
Action: Perform a backup of the virtual disk with the Verify option selected. If the Backup operation is
successful, it indicates that the un-recoverable medium did not affect user data.
If the Backup operation fails, restore the file from a previous backup. After restoring the file, run check
consistency operation:
If the consistency check is successful, no further action is required.
Storage Management Message Reference 159