Reference Guide

Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2331
Description A bad disk block has been reassigned.
Severity OK / Normal / Informational
Cause and Action Cause: The disk has a bad block. Data has been readdressed to another disk block and no data loss has
occurred.
Action: Monitor the disk for other alerts or indications of poor health. For example, you may receive alert
2306. Replace the disk if you suspect there is a problem.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID 2332
Description
A controller hot plug has been detected.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2334
Description
Controller event log: %1
Severity OK / Normal / Informational
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
controller and is displayed with the alert in the alert log. This text is from events in the controller event
log that were generated while Storage Management was not running. This text can vary depending on the
situation. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
136 Storage Management Message Reference