Table 467. Power Supply State Settings Unique (continued)
onlineAndFanFailure(10)
The power supply is online and indicating that its fan is not
working.
powerSupplyIsON(16)
The power supply is indicating that it is on.
powerSupplyIsOk(32)
The power supply is indicating that it is OK.
acSwitchIsON(64)
The power supply is indicating that the AC power switch is on.
onlineandAcSwitchIsON (66)
The power supply is online and indicating that the AC power
supply switch capability is activated.
acPowerIsON(128)
The power supply is indicating that the AC power is on.
onlineAndAcPowerIsON (130)
The power supply is online and indicating that the AC power is
on.
onlineAndPredictiveFail ure(210)
The power supply is online and indicating that it has a
problem.
acPowerAndSwitchAreOn PowerSupplyIsOnIsOkAnd
Online(242)
The power supply is online and OK.
Table 468. Power Supply Type Definitions
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values Meaning of Data Value
powerSupplyTypeIsOther(1)
The power supply type is not one of the following:
powerSupplyTypeIsUnknown(2)
The power supply type is unknown (not known or not
monitored).
powerSupplyTypeIsLinear(3)
The power supply type is a linear power supply.
powerSupplyTypeIsSwitching(4)
The power supply type is a switching power supply.
powerSupplyTypeIsBattery(5)
The power supply type is a battery.
powerSupplyTypeIsUPS(6)
The power supply type is an uninterruptable power supply.
powerSupplyTypeIsConverter(7)
The power supply type is a power converter power supply.
powerSupplyTypeIsRegulator(8)
The power supply type is a regulator power supply.
powerSupplyTypeIsAC(9)
The power supply type is an AC power supply.
powerSupplyTypeIsDC(10)
The power supply type is a DC power supply.
powerSupplyTypeIsVRM(11)
The power supply type is a voltage regulator module (VRM)
power supply.
Table 469. Power Supply Sensor State
Variable Name: DellPowerSupplySensorState
Data Type: Integer
Possible Data Values Meaning of Data Value
presenceDetected(1)
The power supplys presence is detected.
psFailureDetected(2)
The power supply failure is detected.
predictiveFailure(4)
The power supply sensor detects predictive failure
psACLost(8)
The power supplys AC power is lost.
acLostOrOutOfRange(16)
The power supplys AC power is lost or out of range.
110 Server Administrator Group