Reference Guide
Drive bay Intrusion Messages
The drive bay intrusion messages listed are a security measure. Drive bay intrusion means that someone is opening the cover to a system’s
chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.
Event ID — 1258
Description
Drive Bay intrusion has returned to normal sensor location: <location in Drive
bay>
Drive bay location: <Name of drive bay>
Previous state was: <State>
Drive Bay state: <drive bay state>
Severity Informational
Cause A driver bay sensor in the specied system detected that the system cover was opened while the system was
operating. The sensor location, chassis location, previous state, and driver bay state information is provided.
Event ID — 1259
Description
Drive Bay intrusion detected Sensor location: <Location in drive bay>
Drive bay location: <Name of drive bay>
Previous state was: <State>
Drive Bay state: <drive bay state>
Severity Informational
Cause A chassis intrusion sensor in the specied system detected that the system cover was opened while the system
was operating. The sensor location, chassis location, previous state, and chassis intrusion state information is
provided.
Event ID — 1261
Description
Drive Bay Intrusion Detected Extended Sensor location: <Location in drive bay>
Drive bay location: <Name of drive bay>
Previous state was: <State>
Drive Bay state: <drive bay state>
Severity Critical
Server Management Messages 41