Reference Guide

Cable Interconnect Events
The cable interconnect messages in the table are used for detecting errors in the hardware cabling.
Table 19. Cable Interconnect Events
Description Severity Cause
Cable sensor <Name/
Location>Configuration error
was asserted.
Critical This event is generated when the cable is
not connected or is incorrectly connected.
Cable sensor <Name/
Location>Connection was
asserted.
Information This event is generated when the earlier
cable connection error was corrected.
The <name> cable or
interconnect is not connected
or is improperly connected.
Critical This event is generated when the named
cable or interconnect is not connected or is
incorrectly connected.
The <name> cable or
interconnect is connected.
Information This event is generated when named cable
or interconnect earlier cable or interconnect
connection error was corrected.
Battery Events
Table 20. Battery Events
Description Severity Cause
<Battery sensor Name/
Location>Failed was asserted
Critical This event is generated when the sensor
detects a failed or missing battery.
<Battery sensor Name/
Location>Failed was deasserted
Information This event is generated when the earlier
failed battery was corrected.
<Battery sensor Name/
Location>is low was asserted
Warning This event is generated when the sensor
detects a low battery condition.
<Battery sensor Name/
Location>is low was deasserted
Information This event is generated when the earlier low
battery condition was corrected.
The <Battery sensor Name/
Location> battery is low.
Warning This event is generated when the sensor
detects a low battery condition.
The <Battery sensor Name/
Location> battery is operating
normally.
Information This event is generated when an earlier
battery condition was corrected.
The <Battery sensor Name/
Location> battery has failed.
Critical This event is generated when the sensor
detects a failed or missing battery.
System Event Log Messages for IPMI Systems 239