Reference Guide

PDR31
Message A global hot spare has been removed. arg1
Arguments arg1 = PD Name
Detailed
Description
The controller cannot to communicate with a disk that is assigned as a global hot
spare. The disk either failed or was removed. There may also be a bad or loose
cable.
Recommended
Response
Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more
information on checking the cables. If necessary, replace the disk and reassign the
global hot spare.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2202
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR32
Message A dedicated hot spare failed. arg1
Arguments arg1 = PD Name
Detailed
Description
The controller cannot to communicate with a disk that is assigned as a global hot
spare. The disk either failed or was removed. There may also be a bad or loose
cable.
Recommended
Response
Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more
information on checking the cables. If necessary, replace the disk and reassign the
global hot spare.
Category Storage (PDR = Physical Disk)
954