Reference Guide
Recommended
Response
Action
Re-install the memory component. If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
MEM0004
Message Memory device at location arg1 is disabled.
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed. Memory
size is reduced.
Recommended
Response
Action
Re-install the memory component. Review product documentation for supported
memory configurations. If the problem continues, contact support.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
776