Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
HWC8508
Message A device causing an issue in the I/O panel USB port is removed.
Detailed
Description
A device causing an issue in the I/O panel USB port is removed.
Recommended
Response
Action
No response action is required.
Category System Health (HWC = Hardware Config)
Severity Severity 3 (Informational)
Trap/EventID 2331
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
HWC8509
Message One or more PCIe switch heatsinks are not properly attached.
Detailed
Description
The heatsinks are critical for providing cooling to the PCIe switches. If a PCIe
switch stops functioning due to improper cooling, the PCIe subsystem may no
longer function correctly and data loss may occur.
Recommended
Response
Action
Immediately turn off the Chassis by pressing the Chassis power button or removing
chassis input power. The Chassis can be turned off remotely by running the
following RACADM command "racadm chassisaction -m chassis
nongraceshutdown". After turning off, contact your service provider.
642