Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0226
Message An error occurred during DDR memory channel initialization on memory slots:
arg1 .
Arguments arg1 = slot numbers
Detailed
Description
An error occurred during DDR memory initialization during the DDR4 LR-DIMM
Transmit Buffer Training phase.
Recommended
Response
Action
Do the following: 1) Remove input power to the system, 2) Reseat the DIMM
module and 3) Restart the system. If the issue persists, then replace the faulty
memory module(s) identified in the message.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0227
Message An error occurred during DDR memory channel initialization on memory slots:
arg1 .
Arguments arg1 = slot numbers
Detailed
Description
An error occurred during DDR memory initialization during the Memory Buffer
Receive Enable Training - Configuration Read phase.
2205