Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWU8561
Message Unable to downgrade the firmware version because the current hardware
configuration does not support rollback to the earler firmware version.
Detailed
Description
The firmware version selected for rollback does not support the current chassis
hardware configuration.
Recommended
Response
Action
Make sure that firmware version selected for rollback is supported for the current
hardware configuration, such as I/O modules, PSU modules, and servers. For
example, a newer generation PSU may not work with an earlier iDRAC or CMC
firmware. For more information, see the platform Owners Manual or CMC or
iDRAC Release Notes for details.
Category Updates (SWU = Software Change)
Severity Severity 2 (Warning)
Trap/EventID 6314
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWU8662
Message Unable to update the I/O Aggregator (IOA) firmware because of an issue in the
network communication session between CMC and IOA in slot arg1 .
Arguments arg1 = slot ID
1947