Reference Guide

Category System Health (PSU = Power Supply)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU0912
Message A failure detected on power unit arg1 .
Arguments arg1 = number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate in a degraded state. System Performance and
power redundancy may be degraded or lost.
Recommended
Response
Action
Check input power. Re-install the power supply. If problem persists contact
support.
Category System Health (PSU = Power Supply)
Severity Severity 1 (Critical)
OMSA Event ID 5354
OMSA Trap ID 5354
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU0913
Message Power unit arg1 is operating normally.
1086