Reference Guide

Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2321
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2321
Description Single-bit ECC error. The DIMM is critically nonfunctional. There is no further
reporting.
Severity Critical / Failure / Error
Cause and
Action
Cause: The DIMM is malfunctioning. Data loss or data corruption is imminent. No
further alerts are generated.
Action: Replace the DIMM immediately. The DIMM is a part of the controller
battery pack. See your hardware documentation for information on replacing the
DIMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2322
Description The DC power supply is switched off.
Severity Informational
Cause and
Action
Cause: The power supply unit is switched off. Either a user switched off the power
supply unit or it is defective.
Action: Check if the power switch is turned off. If it is turned off, turn it on. If the
problem persists, check if the power cord is attached and functional. If the problem
is still not corrected or if the power switch is already turned on, replace the power
supply unit.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1001
160