SNMP Reference Guide

Description Line Item Explanation
Possible memory module
event cause: <list of
causes>
Specifies a list of possible causes for the memory module event, for example:
Possible memory module event cause: Single bit warning
error rate exceeded
Single bit error logging disabled
Power Supply type:
<type of power supply>
Specifies the type of power supply, for example:
Power Supply type: VRM
Pre-failure state was:
<State>
Specifies the status of the previous memory message, for example:
Pre-failure state was: Failed
Previous redundancy
state was: <State>
Specifies the status of the previous redundancy message, for example:
Previous redundancy state was: Lost
Previous state was:
<State>
Specifies the previous state of the sensor, for example:
Previous state was: OK (Normal)
Processor sensor
status: <status>
Specifies the status of the processor sensor, for example:
Processor sensor status: Configuration error
Redundancy unit:
<Redundancy location
in chassis>
Specifies the location of the redundant power supply or cooling unit in the chassis,
for example:
Redundancy unit: Fan Enclosure
SD card device type:
<Type of SD card
device>
Specifies the type of SD card device, for example:
SD card device type: Hypervisor
SD card state: <State
of SD card>
Specifies the state of the SD card, for example:
SD card state: Present, Failed
Sensor location:
<Location in chassis>
Specifies the location of the sensor in the specified chassis, for example:
Sensor location: CPU1
Temperature sensor
value (in degrees
Celsius): <Reading>
Specifies the temperature in degrees Celsius, for example:
Temperature sensor value (in degrees Celsius): 30
Voltage sensor value
(in Volts): <Reading>
Specifies the voltage sensor value in volts, for example:
Voltage sensor value: 1.693
Understanding Trap Severity
Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical
components for values such as amperage, voltage, and temperature. When an event occurs on your system, the Server
Administrator sends information about one of the following event types to the system management console:
Information/Informational—An event that describes the successful operation of a unit, such as a power supply
turning on or a sensor reading returning to normal.
Warning — An event that is not necessarily significant, but may indicate a possible future problem, such as
crossing a warning threshold.
Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as
crossing a failure threshold or a hardware failure.
531