Command Line Interface Guide

272 omconfig storage Commands
Example Syntax
To start the learn cycle on controller 1, type:
omconfig storage battery action=startlearn
controller=1 battery=0
omconfig Delay Battery Learn Cycle
Use the following omconfig command to delay the battery learn cycle for a
specified period of time. You can delay the battery learn cycle for a maximum
of seven days or 168 hours.
Complete Syntax
omconfig storage battery action=delaylearn
controller=id battery=id days=d hours=h
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, type omreport storage controller to display
the controller IDs and then type omreport storage battery controller=ID to
display the ID for the controller battery.
Example Syntax
To delay the learn cycle for three days and 12 hours on controller 1, type:
omconfig storage battery action=delaylearn
controller=1 battery=0 days=3 hours=12
omconfig Global Commands
The following sections provide the omconfig command syntax required to
execute the global commands. When executed, these commands apply to all
controllers. These global commands also correspond to the global tasks
provided by the Storage tree view object’s Information/Configuration
subtab.