Command Line Interface Guide

132 omconfig: Managing Components Using the Instrumentation Service
ipv6=enable | disable enable: Enables IPv6 stack to load on
iDRAC.
disable: Disables IPv6 stack to unload on
iDRAC.
NOTE: This option requires license to
enable or disable ipv6. If the appropriate
license is not installed or has expired, the
system displays an error message. For
more information, see The Dell Licensing
Management Guide on support.dell.com.
config=advsol characcuminterval=
number
number: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=
number
number: Sets the number of characters.
BMC automatically sends a serial over
LAN data packet that contains the
number of characters as soon as this
number of characters (or greater) has
been accepted from the baseboard serial
controller into the BMC.
enableipmi= true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false true: Enables DRAC NIC.
false: Disables DRAC NIC
NOTE: The enablenic option is supported
on PowerEdge x9xx systems that have
DRAC 5 installed.
Table 4-12. omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess
(continued)
name=value pair 1
config=
name=value pair 2 Description