User's Manual

omconfig Blink Physical Disk
Does my controller support this feature? See "Supported Features."
You can blink the light (light emitting diode or LED display) on one or more physical disks attached to a controller. Use the following omconfig command syntax
to blink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk. See "pdisk=<PDISKID> Parameter" for more information.
To obtain these values, you would enter omreport storage controller to display the controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to blink physical disk 2 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To blink the physical disk described in this example, you would enter:
omconfig storage pdisk action=blink controller=1 pdisk=0:2
See "pdisk=<PDISKID> Parameter on SCSI, SATA, and ATA Controllers" and "Multiple Targets" for more information on physical disk specification. See "RAID
Controller Technology: SCSI, SATA, ATA, and SAS" to identify which technology a controller uses.
Example for SAS Controllers:
To blink the physical disk described in this example, you would enter:
omconfig storage pdisk action=blink controller=1 pdisk=0:2:2
See "pdisk=<PDISKID> Parameter on SAS Controllers" and "Multiple Targets" for more information on physical disk specification. See "SAS RAID Controllers" to
identify which controllers use SAS technology.
omconfig Unblink Physical Disk
Does my controller support this feature? See "Supported Features."
You unblink the light (light emitting diode or LED display) on one or more physical disks attached to a controller. Use the following omconfig command syntax to
unblink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=unblink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk. See "pdisk=<PDISKID> Parameter" for more information.
To obtain these values, you would enter omreport storage controller to display the controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to unblink physical disk 2 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unblink the physical disk described in this example, you would enter: