User's Manual

Example Syntax
In this example, you are assigning physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4. On a SAS controller, the physical
disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To assign the dedicated hot spare described in this example, you would enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:3 assign=yes
See "pdisk=<PDISKID> Parameter on SCSI, SATA, and ATA Controllers" and "Multiple Targets" for more information on physical disk specification. See "RAID
Controller Technology: SCSI, SATA, ATA, and SAS" to identify which technology a controller uses.
Example for SAS Controllers:
To assign the dedicated hot spare described in this example, you would enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:2:3 assign=yes
See "pdisk=<PDISKID> Parameter on SAS Controllers" and "Multiple Targets" for more information on physical disk specification. See "SAS RAID Controllers" to
identify which controllers use SAS technology.
omconfig Unassign Dedicated Hot Spare
Does my controller support this feature? See "Supported Features."
Use the following omconfig command syntax to unassign one or more physical disks that were previously assigned as a hot spare to a virtual disk.
Complete Syntax
omconfig storage vdisk action=assigndedicatedhotspare controller=id vdisk=id pdisk=<PDISKID> assign=no
where id is the controller ID and virtual disk ID. The <PDISK> variable specifies the physical disk. See "pdisk=<PDISKID> Parameter" for more information.
To obtain the values for the controller, virtual disk and physical disk, you would enter omreport storage controller to display the controller IDs and then enter
omreport storage vdisk controller=ID and omreport storage pdisk controller=ID to display the IDs for the virtual disks and physical disks attached to the
controller.
Example Syntax
In this example, you are unassigning physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4. On a SAS controller, the physical
disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unassign the dedicated hot spare described in this example, you would enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:3 assign=no
See "pdisk=<PDISKID> Parameter on SCSI, SATA, and ATA Controllers" and "Multiple Targets" for more information on physical disk specification. See "RAID
Controller Technology: SCSI, SATA, ATA, and SAS" to identify which technology a controller uses.
Example for SAS Controllers:
To unassign the dedicated hot spare described in this example, you would enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1 vdisk=4 pdisk=0:2:3 assign=no
See "pdisk=<PDISKID> Parameter on SAS Controllers" and "Multiple Targets" for more information on physical disk specification. See "SAS RAID Controllers" to
identify which controllers use SAS technology.
omconfig Check Consistency