User's Manual

Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2243 is a clear alert for alert 2242.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2244
Description: A virtual disk blink has been initiated.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1201. See "SNMP Support for Storage Management Alerts" for more information.
2245
Description: A virtual disk blink has ceased.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1201. See "SNMP Support for Storage Management Alerts" for more information.
2246
Description: The controller battery is degraded.
Cause: The controller battery charge is weak. As the battery charge weakens, the battery charger should automatically recharge the battery. If the battery
has already met its recharge limit, then the battery pack needs to be replaced.
Action: Monitor the battery to make sure that it recharges successfully. If the battery does not recharge, then replace the battery pack.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2100
SNMP Trap Number: 1153. See "SNMP Support for Storage Management Alerts" for more information.
2247