Battery Tasks
Do the following to execute a drop-down menu battery task:
Property
Definition
Status
These icons represent the severity or health of the storage component.
Normal/OK
Warning/Non-critical
Critical/Fatal
See "Storage Component Severity" for more information.
Name
This property displays the name of the battery.
State
This property displays the current status of the battery. Possible values are:
Ready The battery is functioning normally.
Degraded The battery needs to be reconditioned.
Reconditioning The battery is being reconditioned. See "Recondition Battery" for more information.
Charging The battery is undergoing the recharge phase of the battery Learn cycle. See "Start Learn Cycle" for more information.
Learning The battery is undergoing the discharge phase of the battery Learn cycle. See "Start Learn Cycle" for more information.
Missing The controller is missing a battery.
Power Low The battery charge is low and the battery needs to be reconditioned.
Failed The battery has failed and needs to be replaced.
Unknown The battery state is not available.
Predicted
Capacity Status
This property displays the charge capacity of the battery. Possible values are:
Ready The battery can be charged to full capacity.
Failed The battery cannot be charged and needs to be replaced.
Unknown The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is
complete.
Learn State
This property displays the current status of the battery Learn cycle. Possible values are:
Active The Learn cycle is currently in progress.
Failed The Learn cycle initiated but then terminated without completing successfully.
Timed out The Learn cycle is timed out.
Requested The Learn State displays Requested when either the controller firmware or a user attempts to initiate a Learn cycle while
the battery is charging. The battery must be fully charged before the Learn cycle begins. The Learn State displays Requested until the
battery is fully charged. When the battery is fully charged, the Learn cycle will begin.
Idle The Learn cycle is currently not active.
Due The Learn cycle is due.
Learn Mode
Auto Storage Management will perform an automatic learn cycle based on the time you set.
Warn The Learn cycle is past the default 90 days.
NOTE: Warn is available only on SAS controllers with firmware version 6.1 and later.
When the battery is in Warn mode, the status of the controller is displayed as degraded.
Next Learn
Time
This property displays the number of days and hours left before the controller firmware initiates the next Learn cycle.
Maximum
Learn Delay
This property displays the maximum number of days and hours that you can delay the battery Learn cycle. The controller firmware
automatically initiates the battery Learn cycle. You cannot stop or pause the Learn cycle, but you can delay it. See "Battery Delay Learn
Cycle" and "Start Learn Cycle" for more information.
Recharge
Count
This property displays the number of times the controller's battery has been recharged.
Max Recharge
Count
This property displays the maximum number of times the controller's battery can be recharged.