SNMP Reference Guide

Traps 655
AC Power Cord Traps
The AC power cord sensor monitors the presence of AC power for an
AC power cord. AC power cord traps provide status and warning information
for power cords that are part of an AC power switch, if your system supports
AC switching.
Table 25-12. AC Power Cord Traps
Trap ID Description Severity Cause
AC Power Cord No Power Nonredundant
1501 AC power cord is not
being monitored
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Information The AC power cord status is
not being monitored. This
occurs when a system’s
expected AC power
configuration is set to
nonredundant. The sensor
location and chassis location
information are provided.
AC Power Cord Normal
1502 AC power has been
restored
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Information An AC power cord that did
not have AC power has had
the power restored. The
sensor location and chassis
location information are
provided.
AC Power Cord Failure
1504 AC power has been lost
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Error An AC power cord has lost
its power. The sensor
location and chassis location
information are provided.