Users Guide

strClassName = "Dell_IndicationStaticValues"
strPropName = "MaxDisplayNotifications"
'*** Establish a connection to the DellOMCI namespace Set objWMIService =GetObject("winmgmts:{impersonationLevel=impersonate," &_
"AuthenticationLevel=pktprivacy}\\" & strComputerName & "\" &_ strNameSpace)
'*** Retrieve the instances of '***Dell_IndicationStaticValues class (there should be 16 instances one for each alert type).
Set ColSystem=objWMIService.execquery ("Select * from " & strClassName)
For each objInstance in ColSystem
'*** Set the value of MaxDisplayNotifications to'0' '*** Set the new value for the property and save the instance objInstance.Properties_.Item
(strPropName).Value = 0 objInstance.Put_ Next
'*** If any errors occurred, let the user know.
If Err.Number <> 0 Then
WScript.Echo "The change to the property failed."
End If
'*** Sub used to display the correct usage of the '***script
Sub Usage()
Dim strMessage
strMessage="incorrectsyntax.Youshouldrun:"&vbCRLF&_"cscript.exe/nologoSampleDisableAlertMessages.vbs<nomdusystème>"
WScript.Echo strMessage
End Sub
Arrêtdesystèmesàdistance
L'exemple VBScript ci-dessousarrêteunclientDell™OMCIàdistance.
'****************************************************
'*** Name: SampleShutdown.vbs
'*** Purpose: To shut down a Dell™ OMCI client.
'***Usage:cscript.exe//nologoSampleShutdown.vbs<nomdusystème>
'***
'*** This sample script is provided as an example only, and has not
'*** been tested, nor is warranted in any way by Dell; Dell disclaims
'*** any liability in connection therewith. Dell provides no
'*** technical support with regard to such scripting. For more
'*** information on WMI scripting, refer to applicable Microsoft®
'*** documentation.
'****************************************************
Option Explicit
'*** Declare variables
Dim strNameSpace
Dim strComputerName
Dim strClassName
Dim strPropValue
Dim objInstance
Dim ObjOutParam
Dim strMethod
'*** Check that the right executable was used to run the script
'*** and that all parameters were passed
If (LCase(Right(WScript.FullName, 11)) = "wscript.exe" ) Or _
(Wscript.Arguments.Count<1)Then
CallUsage()
WScript.Quit
End If
'*** Initialize variables
strNameSpace = "root/Dellomci"
strComputerName = WScript.Arguments(0)
strClassName = "Dell_Configuration"
strPropValue = "Configuration"
strMethod = "Shutdown"
'*** Retrieve the Dell_Configuration class
Set objInstance = GetObject("WinMgmts:{impersonationLevel=impersonate}//" &_
strComputerName&"/"&strNameSpace&":"&strClassName)
'*** Execute the Shutdown method
Set ObjOutParam = objInstance.ExecMethod_(strMethod)
'*** Let the user know whether the method returned success or not