User's Manual

Using the BMC Management Utility 51
Options
-baud
baud_rate
Specifies the communication baud rate over the serial channel, such as 9600 or 19200. It should be in
conformity with the SOL baud rate of the managed server.
-priv
privilege_level
Specifies minimum privilege levels required to establish an SOL session. Possible values are User,
Operator, and Administrator.
-retry count
retry_count
Specifies number of times the BMC will retry sending SOL packages if no acknowledgement is received.
The maximum and minimum values are 7 and 0, respectively.
-retry interval
retry_interval
Specifies the retry time interval that the BMC will wait before resending SOL packets to the remote
console. It is specified in 10 ms increments. For example, if you set 100 as the value, the BMC will wait
1000 ms before retrying to send SOL packages to the remote console. If you specify zero as the value, the
BMC will retry sending instantly, without any time intervals.
Figure 3-11. IPMISH SOL option
sensor
Synopsis
sensor [temp|fan|volt|discrete|numeric][-format <oemlist|legacy>]
Description
This command displays the current status of platform sensors using one of the two possible formats.
OPTIONS
[temp|fan|volt|discrete|numeric]