Users Guide

Table Of Contents
L’état du contrôleur dépend de la mémoire cache préservée. L’état du contrôleur s’affiche comme Degraded (Dégradé) lorsque le
contrôleur dispose d’une mémoire cache préservée. La suppression de la mémoire cache préservée n’est possible que lorsque toutes les
conditions suivantes sont satisfaites :
Le contrôleur ne dispose d’aucune configuration étrangère.
Le contrôleur ne dispose d’aucun disque virtuel déconnecté ou manquant.
Les câbles qui alimentent les disques virtuels ne sont pas déconnectés.
Managing PCIe SSDs
Peripheral Component Interconnect Express (PCIe) solid-state device (SSD) is a high-performance storage device designed for solutions
requiring low latency, high Input Output Operations per Second (IOPS), and enterprise class storage reliability and serviceability. The PCIe
SSD is designed based on Single Level Cell (SLC) and Multi-Level Cell (MLC) NAND flash technology with a high-speed PCIe 2.0, PCIe
3.0, or PCIe 4.0 compliant interface. In 14th generation of PowerEdge servers, we have three different ways to connect SSDs. You can
use an extender to connect the SSDs via backplane, directly connect the SSDs from backplane to mother board using slimline cable
without extender, and use HHHL (Add-In) card which sits on the motherboard.
NOTE:
14th generation of PowerEdge servers are supporting Industry standard NVMe-MI specification based NVMe SSDs
PERC 11 supports PCIe SSD/NVMe devices behind PERC inventory monitoring and configuration.
Using iDRAC interfaces, you can view and configure NVMe PCIe SSDs.
The key features of PCIe SSD are:
Hot plug capability
High-performance device
In few of the 14th generation of PowerEdge servers, up to 32 NVMe SSDs are supported.
You can perform the following operations for PCIe SSDs:
Inventory and remotely monitor the health of PCIe SSDs in the server
Prepare to remove the PCIe SSD
Securely erase the data
Blink or unblink the device LED (Identify the device)
You can perform the following operations for HHHL SSDs:
Inventory and real-time monitoring of the HHHL SSD in the server
Failed card reporting and logging in iDRAC and OMSS
Securely erasing the data and removing the card
TTY logs reporting
You can perform the following operations for SSDs:
Drive status reporting such as Online, Failed, and Offline
NOTE: Hot plug capability, prepare to remove, and blink or unblink the device LED is not applicable for HHHL PCIe SSD devices.
NOTE: When NVMe devices are controlled behind SW RAID, prepare to remove and cryptographic erase operations are not
supported, blink and unblink are supported.
Inventaire et surveillance de SSD PCIe
Les informations d’inventaire et de surveillance suivantes sont disponibles pour les SSD PCIe :
Informations relatives au matériel :
Carte de l’extenseur SSD PCIe
Fond de panier SSD PCIe
Si le système est équipé d'un backplane PCIe dédié, deux FQDD sont affichés. Un FQDD est destiné aux lecteurs standard et
l'autre aux disques SSD. Si le backplane est partagé (universel), un seul FQDD s'affiche. Dans le cas où les disques SSD sont
directement connectés, le FQDD de contrôleur est affiché en tant que CPU.1, ce qui indique que le disque SSD est directement
connecté à l'UC.
L’inventaire des logiciels inclut uniquement la version du micrologiciel du SSD PCIe.
Managing storage devices