CLI Guide

Version Description
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the C-Series and E-Series. Maximum rate
limit on E-Series reduced from 4000 to 3000.
7.4.1.0 Introduced
Example
Dell(conf-if-vl-2)# vlan-stack compatible
Dell(conf-if-vl-2-stack)#protocol-tunnle rate-limit 100
<<<<<<<< VLAN stack mode
Dell(conf-if-vl-2-stack)#show config
!
interface Vlan 2
no ip address
mtu 1000
vlan-stack compatible
protocol-tunnel rate-limit 100
shutdown
Related
Commands
show protocol-tunnel — displays tunneling information for all VLANs.
show running-config — displays the current configuration.
show protocol-tunnel
Display protocol tunnel information for all or a specified VLAN-Stack VLAN.
Syntax
show protocol-tunnel [vlan vlan-id]
Parameters
vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to
display information for the one VLAN. The range is from 1 to
4094.
Defaults none
Command Modes EXEC
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
Service Provider Bridging
1639