Release Notes

Resolution
You must manually enable or disable the vFlash functionality after the firmware update as required. To
do this, select or clear the vFlash Enabled option in the iDRAC7 Web interface, or use RACADM or
WinRM remote service commands.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge(TM) systems.
Issue 7:
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the
sequence of events reported in the Lifecycle Log (or corresponding SNMP traps/email alerts) for storage
devices may not exactly match the sequence in which they occurred.
Resolution
The current state or attribute of the storage device can be checked in any of the iDRAC7 interfaces
(example, iDRAC7 Web interface, RACADM and so on).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 8:
Description
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a
non-redundant path, the reported connected port value of the enclosures may not be accurate.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 9:
Description
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its
components (that is, EMM, PSU, fan, and temperature sensors) is reported as critical.
Resolution
If the storage enclosure is disconnected accidentally, reconnect it to get back to normal state. If it is
intentional, perform iDRAC7 reboot or server power cycle to remove the enclosure entries from the
consoles.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 10:
Description
Logging in to iDRAC7 Web interface fails with the error message 'RAC0218: The maximum number of
user sessions is reached'.
When the temporary folder used by iDRAC7 components is full, it is possible that authentication fails and
this error is displayed.
Resolution
Power cycle iDRAC7 to clear the temporary space.