Release Notes
Workaround
Ignore this entry in the inventory
Systems affected PowerEdge R7525
Tracking number 153974
Webserver restarts after remote presence port
number is updated
Description
Changing the Remote Presence Port number through virtual console settings page may cause a system
restart, further causing a session timeout for iDRAC GUI.
Workaround
N/a
Systems affected All systems supported by this release.
Tracking number 144597
Getting an error SWC0018 during OS installation
Description
Modifying BIOS Boot Mode while installing operating system thorough Lifecycle Controller GUI, an error
"SWC0018" is displayed.
Workaround
This message does not impact the installation, click OK to proceed.
Systems affected All systems supported by this release.
Tracking number 143561
WSMan query with space between attributes fails
Description
Query parsing error is observed while parsing the SQL query with a space in some properties.
Workaround
Scripts may be edited to remove the space between properties to be selected in the WSMan Query
parameter.
Systems affected All systems supported by this release.
Tracking number 153493
Attributes for CNA cards not displayed through
Redfish or RACADM interface
Description
If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN,
WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not
displayed when Get commands are performed in Redfish and RACADM interfaces.
Workaround N/A
Systems affected All systems supported by this release.
Tracking number 151560
24 Known issues — To be fixed in future releases