Release Notes

Table Of Contents
Delayed response when iDRACs network settings are
reconfigured
Description When a Remote File Share is mounted on the iDRAC, changing network-related settings, or OS-BMC
settings, on the iDRAC will take two minutes to apply. During this extended time, the iDRAC will not be
reachable until after the reconfiguration is completed.
Workaround Disconnect Remote File Share mounts before modifying network settings.
Systems affected All systems supported by this release.
Tracking number 152168
Integrated/Embedded NIC displaying status as
Unknown
Description Systems with only Integrated/Embedded NIC may report the status as Unknown.
Workaround Reboot the iDRAC or the host
Systems affected All systems supported by this release.
Tracking number 151475
No errors when the selected component and the
selected device firmware do not match
Description
While updating a component firmware using Component or Device update filter in OME-Modular, if the
DUP device firmware selected is for another component, then the update goes through without any
errors and device firmware for the relevant component is updated instead of the one selected.
Workaround Use the firmware rollback option to downgrade the firmware to the previous version.
Systems affected All MX platform systems supported by this release.
Tracking number 150783
SEL missed in the LCL during Racreset.
Description
During iDRAC reset, if SEL is getting logged, it might not be forwarded to LCL and its corresponding
event is not forwarded to registered destination (SNMP, REDFISH, so on)
Workaround If SEL is cleared, this issue will not be seen in the next Racreset.
Systems affected All systems supported by this release.
Tracking number 154003
PCIe SSD Backplane 2 is displayed as unknown
Description
On the storage enclosure page, PCIe SSD Backplane 2 is displayed as unknown instead of showing the
faulty physical drive. This issue is observed if there is any unsupported/unresponsive physical drive in the
enclosure.
Workaround Remove the unsupported/unresponsive physical drive from the enclosure and perform racadm racreset.
20 Known issues To be fixed in future releases