Systems affected All root port attached NVMe configuration systems.
Tracking number 145300
Firmware update operation not scheduled through
WSMan
Description On Modular servers the firmware update operation on backplane cannot be scheduled through the
WSMAN interface.
Workaround Update firmware by using other interfaces such as GUI, LCUI, Redfish.
Systems affected All modular systems supported by this release.
Tracking number 145300
Access to serial interface fails.
Description The serial interface cannot be accessed with a user account that has Easy 2FA enabled. It is because the
serial interface is an exempted interface which is not supported on Easy 2FA feature.
Workaround Disable 2FA on user account, and retry the operation.
Systems affected All systems supported by this release.
Tracking number 152106
Delayed response when iDRAC's network settings are
reconfigured
Description
When a Remote File Share is mounted on the iDRAC, changing network-related settings, or OS-BMC
settings, on the iDRAC will take two minutes to apply. During this extended time, the iDRAC will not be
reachable until after the reconfiguration is completed.
Workaround Disconnect Remote File Share mounts before modifying network settings.
Systems affected All systems supported by this release.
Tracking number 152168
Remote File Share (RFS) does not stay connected
after downgrading iDRAC
Description
RFS does not stay connected after downgrading the iDRAC and user cannot reconnect and will not have
access to the files mapped through RFS.
Workaround Disable and re-enabling Virtual Media or restarting iDRAC
Systems affected All modular systems supported by this release.
Tracking number 151995