Release Notes

Table Of Contents
PR1 & PR10 Lifecycle logs displayed during Retire and
Repurpose operation
Description PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is
executed. This doesn't impact server functionality.
Workaround N/a
Systems affected All systems supported by this release.
Tracking number 186119
CPU PPIN in Hardware inventory in IDRAC GUI shows
as Not Supported
Description CPU PPIN in Hardware inventory in IDRAC GUI shows as "Not Supported" after iDRAC firmware update
from previous version to 4.40.00.00.
Workaround Reboot the host so the CSIOR runs and populates supported CPU PPINs in Hardware inventory.
Systems affected All systems supported by this release.
Tracking number 185523
VLAN gets disabled after successful configuration in
Lifecycle controller
Description
After an IPv6 configuration, incorrect VLAN values are displayed when network setting page is reopened
in the Lifecycle Controller.
Workaround Select the configured port in Network Settings page to see configured VLAN values for the port.
Systems affected All systems supported by this release.
Tracking number 185043
Performing GET method on chassis PCIe slots
displays all PCIe slots
Description
iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries
are seen under one sled even though only few are associated with that particular sled.
Workaround N/a
Systems affected PowerEdge FC640, PowerEdge R740XD
Tracking number 172943
Known issues To be fixed in future releases 23