Reference Guide
rollback
Descriptio
n
Allows you to roll back the firmware to an earlier version.
Synopsis
racadm rollback <FQDD>
NOTE: To get the list of available rollback versions and
FQDDs, run the racadm swinventory command.
Input <FQDD>: Specify the FQDD of the device for which the rollback
is required.
Example
racadm rollback iDRAC.Embedded.1-1
RAC1056: Rollback operation initiated
successfully.
sensorsettings
Descripti
on
Allows you to perform threshold settings of the sensor.
To run this subcommand, you must have Configure iDRAC
privilege.
NOTE: An error message is displayed when the following is
performed:
• A set operation is performed on an unsupported FQDD.
• Out of range settings is entered.
• Invalid sensor FQDD is entered.
• Invalid threshold level filter is entered.
Synopsis
racadm sensorsettings set <FQDD> -level Min
<value>
Input
• <FQDD> — Sensor or corresponding sensor FQDD which
needs a threshold configuration. Run the command, racadm
getsensorinfo
to view the sensor FQDD. The R/W field in
the output getsensorinfo indicates if the sensor thresholds
can be configured. Replace the <FQDD> field with the
corresponding sensor FQDD that needs a threshold
configuration.
• -level — threshold level for the sensor setting. Values are
Max or Min.
96