Release Notes

Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 16:
Description
iDRAC7 Web interface does not respond when using Internet Explorer.
Resolution
Close all Internet Explorer sessions and open it again to access iDRAC7 Web interface.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 17:
Description
When a driver pack DUP update is performed, the following message is recorded in the Lifecycle log after
the driver pack update entry.
RAC0400: iDRAC memory low iDRAC is running low on memory. System performance may be degraded.
Recommended Action: No response action is required.
Resolution
No workaround is required. This is a normal condition when the memory is lower than the threshold for
around 30 seconds and returns to normal after the driver pack update finishes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 18:
Description
Resetting iDRAC7 to default values action may take between four to six minutes to complete.
Resolution:
Wait for iDRAC7 to reboot before performing any other action.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 19:
Description
In the iDRAC7 Web interface -> Overview -> Server -> Power/Thermal -> Power Monitoring tab ->
Power section, the Power Unit selector only changes the unit of measure. Due to the oscillating nature
of power, the Present Reading cannot be displayed as units for Current (Amps).
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 20:
Description
On all Intel NICs, each port cannot be assigned different iSCSI initiator name (by assigning the value for
IscsiInitiatorName). If the name is changed for one port, the same change is applied to all ports.